Paradyne Network Card SAM2000GV 12 User Manual

Interface Module User Guide  
SAM2000GV-12  
12-Port VoSHDSL Access Multiplexer  
Also: SAM2000QV-12 (2B1Q) and SAM2000V-12 (CAP)  
1.0 VoSDSL ACCESS MODULE MODELS  
VoSDSL access multiplexers are intended for use in Net to Net Technologies' IPD12000 and IPD4000  
DSLAMs. Model types vary by the SDSL line code utilized.  
1.1 SAM2000GV-12  
The SAM2000GV-12 operates with Transmission Convergence/Pulse Amplitude Modulation  
(TC/PAM) line code: a sixteen-level PAM technique which incorporates advanced Trellis code,  
precoding, spectral shaping, equalization circuits and forward error correction. Otherwise known as  
G.SHDSL or SHDSL.  
1.2 SAM2000QV-12  
The SAM2000QV-12 operates with Two Binary, One Quaternary (2B1Q) line code: a four-level PAM  
technique which reduces the signaling rate to half of the bit rate.  
1.3 SAM2000V-12  
The SAM2000V-12 operates with Carrierless Amplitude and Phase (CAP) modulation line code:  
transmit and receive signals are modulated into two wide-frequency bands that can pass through a  
filter without being attenuated.  
Throughout this document, "SAM2000GV" is utilized to indicate all three VoSDSL access multiplexer models;  
information given applies to all three models except as individually stated or otherwise noted.  
NOTE  
 
210-0000045 rev04  
VoSHDSL RJ21 Port Pinout  
PORT  
Ring  
Tip  
1
2
3
4
5
6
7
8
9
10 11 12  
1
2
3
4
5
6
7
8
9
10 11 12  
SDSL  
26 27 28 29 30 31 32 33 34 35 36 37  
Ring 14 15 16 17 18 19 20 21 22 23 24 25  
Tip 39 40 41 42 43 44 45 46 47 48 49 50  
VOICE  
(pins 13 and 38 are not used)  
2.3.2 Voice Connection(s)  
The SAM2000GV has Foreign Exchange Office (FXO) capability for connection to voice switches  
or Private Branch Exchanges (PBXs). Net to Net Technologies' remote VoSHDSL modems  
(SNE2000GV-Ss) have Foreign Exchange Station (FXS) capability for connection to an analog  
station (phone, fax, modem, etc.). Individual voice connections can be verified via the Voice  
Link (Lnk) LED on the front of the remote SNE2000GV-S; it will flash or pulse green to indicate  
activity. Refer to Net to Net's SNE2000GV-S Installation Instructions for further information.  
2.3.3 SHDSL Connection(s)  
Verify your SHDSL connections; the SHDSL Link (LK) LED for each connected port on the  
SAM2000GV will illuminate solid or pulsing green. Link up time for SHDSL connections  
between the SAM2000GV and remote VoSHDSL modems can vary from one to five minutes  
depending on the quality, gauge and distance of the copper cables. Default bandwidth is 272  
kbps.  
3.0 SAM2000GV DEFAULT CONFIGURATIONS  
No configuration is necessary for the SAM2000GV to operate at default settings.  
3.1 IP DSLAM Management  
3.1.1 User Access  
All usernames and passwords are case sensitive.  
NOTE  
3.1.1.1 Network Management System (NMS) and Command Line Interface (CLI)  
ACCESS  
read/write superuser  
read only general  
USERNAME PASSWORD  
Password  
Password  
 
210-0000045 rev04  
3.1.1.2 Simple Network Management Protocol (SNMP)  
ACCESS  
read/write Password  
read only Password  
COMMUNITY STRING  
3.1.2 Management Parameters  
The parameter defaults listed are common to all DSLAM/MUM model types. Some models  
have additional configuration possibilities; refer to the User Guide and/or Installation  
Instructions for your particular model.  
PARAMETER  
DEFAULT CONFIGURATION  
0.0.0.0  
Gateway  
Inband Management  
Inband Management VLAN ID  
IP Address: IPD12000 Slot 13  
IP Address: IPD12000 Slot 14  
IP Address: IPD4000 Slot 5  
off  
0 (off)  
192.168.254.252  
192.168.254.253  
192.168.254.252  
Management IP Address Filter Range 0.0.0.0 - 255.255.255.255 (all)  
Subnet Mask  
255.255.255.0  
3.2 SAM2000GV Port Parameters  
PARAMETER  
DEFAULT CONFIGURATION  
Circuit Identification n/a (no default)  
Back-bone VLAN  
Flood  
0 (off)  
uplink  
IP Range 1  
IP Range 2  
Priority (VLAN)  
Protocol  
0.0.0.0 - 255.255.255.255 (all)  
0.0.0.0 - 0.0.0.0  
0 (none)  
all  
Speed  
272 kbps  
0 - 0 (off)  
VLAN Range  
 
210-0000045 rev04  
4.0 SAM2000GV MANAGEMENT  
Once your SAM2000GV has been installed, bandwidth and other configurations are software selectable via  
your IP DSLAM's MUM. Dependent upon the MUM model installed, the SAM2000GV may be configured via  
Command Line Interface (CLI), Simple Network Management Protocol (SNMP) and/or Net to Net  
Technologies' web-based Network Management System (NMS).  
If your IP DSLAM is newly installed, configuration of the DSLAM's IP Address, Subnet Mask and Gateway  
must be completed, via CLI or NMS, before you will be able to access management data or configure any  
other parameters. Refer to the CLI Management User Guide (http://www.nettonet.com/support/docs/210-  
0000052) or to the NMS Management User Guide (http://www.nettonet.com/support/docs/210-  
0000048) for initial configuration instructions.  
If you have an IPD12000 with two MUMs, configuration alterations can be made to a SAM2000GV through either MUM;  
most configuration(s) will be saved to the NVRAM of both. Refer to your MUM Installation Instructions for specifics.  
NOTE  
4.1 Via Command Line Interface (CLI)  
4.1.1 Establish a Connection With Your IP DSLAM  
Establish a connection between your IP DSLAM and your PC, either directly (through the COM  
port on the MUM faceplate) or, if your DSLAM has been configured to allow inband  
management, across your local network.  
4.1.2 Launch Your Terminal Emulator  
Launch a terminal emulator program on your PC. Net to Net Technologies' copyright  
information will appear on your screen, followed by a request for username.  
4.1.3 Log In  
Log in with your assigned username and password. For SAM2000GV configuration, you must  
log in as a superuser (general users have read only access). If your username and/or password  
are unknown, contact your System Administrator or Information Technology Manager for  
assistance.  
Once you have logged in as a superuser, you will be able to make configuration changes to the  
SAM2000GV, and any other interface modules installed in your IP DSLAM, as desired. For more  
detailed information regarding SAM2000GV configuration via CLI, refer to Net to Net's CLI  
4.2 Via Net to Net's Network Management System (NMS)  
4.2.1 Establish a Connection With Your IP DSLAM  
Establish a connection between your IP DSLAM and your PC, either directly (through the  
10/100 Ethernet MGMT port on the MUM faceplate) or, if your DSLAM has been configured to  
allow inband management, across your local network. For direct connections, verify that the  
MGMT LNK LED on the MUM faceplate is illuminated.  
 
210-0000045 rev04  
4.2.2 Launch Your Web Browser  
Launch a web browser on your PC such as Microsoft Internet Explorer or Netscape Navigator.  
4.2.3 Enter Your DSLAM's IP Address  
Enter the DSLAM's IP Address into the address field at the top of your browser window and  
press the Enter key.  
4.2.4 Log In  
Log in with your assigned username and password. For SAM2000GV configuration, you must  
log in as a superuser (general users have read only access). If your username and/or password  
are unknown, contact your System Administrator or Information Technology Manager for  
assistance.  
Once you have logged in as a superuser, you will be able to make configuration changes to the  
SAM2000GV, and any other interface modules installed in your IP DSLAM, as desired. For more  
detailed information regarding SAM2000GV configuration via NMS, refer to Net to Net's NMS  
4.3 Via Simple Network Management Protocol (SNMP)  
The MUM200-2 does not have SNMP capabilities; you must have a MUM2000-2 installed in your IP DSLAM in  
order to access DSLAM management or any interface modules via SNMP.  
NOTE  
4.3.1 Establish a Connection With Your IP DSLAM  
Establish a connection between your IP DSLAM and your PC, either directly (through the  
10/100 Ethernet MGMT port on the MUM faceplate) or, if your DSLAM has been configured to  
allow inband management, across your local network. For direct connections, verify that the  
MGMT LNK LED on the MUM faceplate is illuminated.  
4.3.2 Launch Your MIB Browser  
Launch a MIB browser program on your PC. If you have not yet downloaded the necessary  
MIBs to your PC or local network, you can obtain the Net to Net enterprise MIBs from  
ftp://ftp.nettonet.com/download/mibs and the supported portions of MIB-II from the Internet  
Engineering Task Force RFC 1213 at http://www.ietf.org/rfc.html. After downloading the MIBs,  
you will need to compile them into your MIB browser; refer to your MIB browser user manual  
for further instruction.  
Once the MIBs have been compiled, you will be able to make configuration changes to the  
SAM2000GV, and any other interface modules installed in your IP DSLAM, as desired. For more  
detailed information regarding SAM2000GV configuration via SNMP, refer to Net to Net's SNMP  
 
210-0000045 rev04  
5.0 BANDWIDTH AND DISTANCE  
Parameters common to all interface module models are defined in the CLI, NMS and SNMP Management User Guides.  
Bandwidth, however, is specific to the SAM2000GV-12, SAM2000QV-12 and SAM2000-12.  
NOTE  
The SAM2000GV-12, SAM2000QV-12 and SAM2000-12 each have nine SHDSL bandwidth options;  
default is 272 kbps. Distance capabilities at each bandwidth vary, dependent upon the type of line code  
being utilized. Distances listed below assume the use of 26 American Wire Gauge (AWG) cable;  
connections made with cable of a greater gauge will link up at greater distances. The ports on your module  
may not link up if your cables are in poor condition or if cable distances are greater than the configured  
bandwidth will support. Although it is sometimes possible for links to be achieved under such conditions,  
traffic quality may be effected (e.g., packets may be dropped).  
SHDSL BANDWIDTH kbps  
2,320 2,064 1,552 1,040 784  
11,300 12,200 12,800 16,000 16,800 18,400 19,400 20,200 25,400  
meters 3,444 3,719 3,901 4,877 5,121 5,608 5,913 6,157 7,742  
feet 10,400 10,800 13,400 14,800 15,800 17,400 18,200 19,200 23,800  
meters 3,170 3,292 4,084 4,511 4,816 5,304 5,547 5,852 7,254  
feet 11,000 11,900 12,600 15,500 16,000 17,900 18,900 23,100 24,700  
meters 3,353 3,627 3,840 4,724 4,877 5,456 5,761 7,041 7,529  
528  
400  
272  
144  
SAM2000GV-12  
TC/PAM line code:  
SHDSL  
feet  
SAM2000QV-12  
2B1Q line code  
DISTANCE  
SAM2000GV-12  
CAP line code  
6.0 ADDITIONAL INFORMATION  
6.1 Data Storage  
Configuration backup is inherent in Net to Net Technologies' IP DSLAMs. SAM2000GV default  
parameters remain in place unless changed via CLI, NMS or SNMP. Once changed, new  
configurations are automatically recorded in both RAM and NVRAM.  
6.1.1 Memory  
6.1.1.1 Random Access Memory (RAM)  
Data stored in SAM2000GV RAM will be erased if the module is removed from your IP  
DSLAM or if your IP DSLAM loses power.  
6.1.1.2 Non-Volatile Random Access Memory (NVRAM)  
Data stored in the NVRAM of your IP DSLAM's MUM will remain intact (even if your IP  
DSLAM loses power) unless deliberately cleared or reconfigured.  
 
210-0000045 rev04  
6.1.2 Local Files  
Management and interface module configurations can be saved on your PC, or local network,  
as a backup and/or for use as a template for future configurations, via the MUM in your IP  
DSLAM. Management configurations and all interface module port configurations are saved  
concurrently; SAM2000GV configurations cannot be saved independently. Once your IP DSLAM  
has been configured as desired (including the SAM2000GV), settings can be flash uploaded  
(to a local file) through a Trivial File Transfer Protocol (TFTP) tool with a GET command and the  
following information:  
6.1.2.1 Backup  
An IP DSLAM backup file records ALL management and port configurations.  
ITEM  
DATA NEEDED FOR BACKUP  
EXAMPLE  
193.166.254.98  
Host Name  
DSLAM_IP Address (xxx.xxx.xxx.xxx)  
Remote Filename NVR_BACKUP.BIN.[superuser password] nvr_backup.bin.Password  
Local Filename  
user preference  
dslam27_mum13_backup.bin  
6.1.2.2 Template  
An IP DSLAM template file records all management and port configurations EXCEPT the  
MUM's IP Address.  
ITEM  
DATA NEEDED FOR BACKUP  
EXAMPLE  
Host Name  
DSLAM_IP Address (xxx.xxx.xxx.xxx) 193.166.254.98  
Remote Filename NVR_CFG.BIN.[superuser password] nvr_cfg.bin.Password  
Local Filename user preference n2n_dslam12000_template.bin  
Configuration files can also be flash downloaded FROM a local file TO an IP DSLAM, simply  
replace the GET command with a PUT command. Refer to your TFTP user manual for further  
instruction.  
6.2 LED Indications  
LED  
State  
Indication  
Additional Information  
Power (PWR)  
solid green  
SAM2000GV is  
operational  
If the Power LED is not illuminated, it is unlikely that the  
SAM2000GV-12 is receiving power, in which case none of  
the LEDs will be illuminated.  
SHDSL Link (Lk)  
pulsing  
green  
SHDSL connection is  
established and active  
The SHDSL link is operational and traffic is flowing.  
solid green  
problematic SHDSL  
connection  
A connection exists but there is indication of a problem  
with the SHDSL line.  
no  
no SHDSL connection  
illumination  
 
210-0000045 rev04  
SHDSL Data  
Reception (Rx)  
flashing  
amber  
SHDSL activity  
The port is receiving data from the remote VoSHDSL  
modem or statistical packets from your IP DSLAM's  
management.  
solid amber heavy Rx traffic  
The port is receiving large amounts of data from the  
remote VoSHDSL modem or statistical packets from your  
IP DSLAM's management.  
no  
no activity  
A link may exist but the port is not receiving any data  
from the remote VoSHDSL modem or statistical packets  
from your IP DSLAM's management.  
illumination  
SHDSL Data  
Transmission (Tx) amber  
flashing  
SHDSL activity  
The port is transmitting data to the remote VoSHDSL  
modem.  
solid amber heavy Tx traffic  
The port is transmitting large amounts of data to the  
remote VoSHDSL modem.  
no  
no activity  
A link may exist but the port is not transmitting any data  
to the remote VoSHDSL modem.  
illumination  
(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid,  
less constant rate.)  
6.3 Country Codes  
All of Net to Net Technologies' voice capable products include Country Codes. Country Codes are  
software coefficients that control the Digital Signal Processor (DSP) and analog to digital CODer and  
DECoder (CODEC) characteristics which enable VoDSL equipment to comply with the  
telecommunication regulatory requirements of the region and/or country of installation.  
6.4 Regulatory Compliance for Class A Equipment  
The following regulatory compliance information applies to the SAM2000GV-12, SAM2000QV-12  
and/or SAM2000G-12 as installed in Net to Net Technologies' IP DSLAMs.  
6.4.1 US Federal Communications Commission (FCC)  
Note: This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference when the equipment is operated in a commercial  
environment. This equipment generates, uses and can radiate radio frequency energy and, if  
not installed and used in accordance with the instruction manual, may cause harmful  
interference to radio communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be required to correct the  
interference at his own expense.  
Caution: Changes or modifications not expressly approved by the manufacturer could void the  
user’s authority to operate the equipment.  
6.4.2 Industry Canada  
This Class A digital apparatus complies with Canadian ICES-003.  
Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.  
 
210-0000045 rev04  
6.4.3 Europe  
This Class A product complies with European Norm EN55022.  
Warning: In a domestic environment this product may cause radio interference in which case  
the user may be required to take adequate measures to correct the situation.  
210-0000045 rev04  
© Copyright 2003 Net to Net Technologies, Inc.  
™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc.  
Worldwide Headquarters  
Net to Net Technologies  
112 Corporate Drive  
Portsmouth, NH 03801  
USA  
EMEA Headquarters  
Net to Net Technologies  
Victoria House 19 Park Way  
Newbury Berkshire RG14 1EE  
UK  
+1 877-638-2638  
+44 (0) 1635 570950  
 
210-0000045 rev04  

MTD Lawn Mower 110 112A User Manual
National Computer Hardware LM95235 User Manual
New Holland Lawn Mower T8010 User Manual
Nokia Bluetooth Headset HDW 2 User Manual
Olympus MP3 Player MR F20 User Manual
Omron Switch B3F User Manual
Optiview Security Camera 22XSPDIN User Manual
Ozaki Worldwide Speaker EM985 User Manual
Panasonic Air Conditioner CS MC12DKU User Manual
Panasonic Air Conditioner CW0 C121MU User Manual